How To Plumb Water Pipes Under Concrete Floor

  1. I am putting in a new concrete floor at one cease of my kitchen and want to run a h2o pipe in it to service a sink. Can someone communication on the right way to do this and which pipe i need.
    Thank you all.
  2. hep , plastic pipage and yes greyness
  3. any piping but a proper plumber will do it in copper. it must be layed in a duct for time to come access.
  4. I donut that , why a duct every bit it would exist in one length , no need to access
  5. if yous put the copper into a concrete floor it volition corrode and 5 yrs from now you could be digging it up.
    Putting it in a duct non merely goes by build regs it likewise cant be damaged and is accessable.
  6. larry 123 , if you put plastic pipe in it wont corrode and no need for ducts , building regs , the chap wants to put a sink in ,come up on , plastic
  7. Howdy Richard.

    Will the hot exist fed past a combi boiler? If and so, a quick and simple solution is to run your continuous lengths of 15mm pipes inside a couple of lengths of 22mm.

    All the same, if you are doing things past the regs...

  8. deacon
    if you lot read the regs properly and pipe manufacturers instructions you volition find all pipework existence copper or plastic has to be in a duct or conduit.

    water regs schedule 2.7 and bs8000

  9. what a load of b****** , hes putting in a sink what all the regs about, if yous want to take on the deacon be prepared to swallow your words
  10. you talk what. don't care if its a sink or a bird bath
  11. y'all talk what. don't care if its a sink or a bird bath

    standby to exist humiliated or are you lot going to retract your statement , building regs indeed , are yous to suggest that this chap must utilise for building regs to place a sink , love people like you lot who quote all this rubbish , be gear up for the deacon

  12. you don't apply for them they are for the wallys that abuse them
  13. you talk what. don't intendance if its a sink or a bird
    bath

    standby to exist humiliated or are you going to retract
    your statement , building regs indeed , are you to
    suggest that this chap must employ for edifice regs
    to identify a sink , love people like you who quote all
    this rubbish , exist ready for the deacon

    There are standards that should be used when doing ANY building piece of work, plumbing, electrics whether building regs or planning application has been applied for or non.

    As far as I know, a pipe layed in concrete must have room for expansion(more than one mode to attain that)and must be continuous(no joints), then there are only two.

    No application doesn't mean you can do things how yous like.

    Mr. HandyAndy - actually

  14. As far every bit I know, a piping laid in concrete must have room for expansion(more than than ane way to achieve that)and must be continuous(no joints), so there are just two.

    no andy , the plumber said he needed access to the pipes , this is what I queried ,one said run 22mm with 15mm inside , why , one said copper ,building regs are fine if you lot piece of work to them and if they are applicative to the job , you will query this and I will have to tell you with a answer , a nice ane of course....mate

  15. if you read the regs properly and pipe manufacturers instructions you will find all pipework being copper or plastic has to be in a duct or conduit.

    water regs schedule 2.7 and bs8000

    is that and so plumb , go ready to eat your words

  16. If you accept information relating to this deacon, Mail service IT At present.

    Or shut upwardly and exist considered a fool.(once more)

    Mr. HandyAndy - really

  17. Then it should all get quiet for a while now.

    Mr. HandyAndy - actually

  18. Yes, it'southward all very repose hither, isn't information technology ?

    Mr. HandyAndy - really

  19. ­

    ­ New Member


    if you read the regs properly and piping manufacturers
    s instructions you volition find all pipework being
    copper or plastic has to be in a duct or conduit.

    water regs schedule 2.seven and bs8000

    Then y'all put your undefloor heating pipes in a duct do you?

Share This Page

How To Plumb Water Pipes Under Concrete Floor,

Source: https://community.screwfix.com/threads/water-pipes-under-new-concrete-floor.7865/

Posted by: wayswee1997.blogspot.com

0 Response to "How To Plumb Water Pipes Under Concrete Floor"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel